Compare commits

...

4 Commits

Author SHA1 Message Date
0067a0b8a9 More doxygen comments added.
All checks were successful
continuous-integration/drone/push Build is passing
2020-12-12 17:48:36 +01:00
602ec3add6 Adding doxyfile to follow standard
All checks were successful
continuous-integration/drone/push Build is passing
2020-12-12 15:57:03 +01:00
be24ee7816 Cleanup files. Moving doxygen output to seperate folder.
All checks were successful
continuous-integration/drone/push Build is passing
2020-12-11 20:15:47 +01:00
b927b1fdb9 First attempts with Doxygen 2020-12-11 20:10:17 +01:00
6 changed files with 2684 additions and 10 deletions

4
.gitignore vendored

@ -1,6 +1,4 @@
.pioenvs
.piolibdeps
.pio
data/homie/config.json
nbproject
.vscode
output/doxygen

2608
Doxyfile Normal file

File diff suppressed because it is too large Load Diff

@ -4,3 +4,6 @@ build:
otaupload:
pip install -r .pio/libdeps/nodemcu/Homie/scripts/ota_updater/requirements.txt
python .pio/libdeps/nodemcu/Homie/scripts/ota_updater/ota_updater.py -l mqtt.jcktrue.dk -i 18fe34f2f987 .pio/build/nodemcu/firmware.bin
docs:
doxygen .\.doxygen

@ -1,15 +1,36 @@
/**
* \file
* \class Config
*/
#ifndef CONFIG_H
#define CONFIG_H
#ifndef VERSION
//SEMVER style version
/**
* \brief Version string.
* Update as needed. Formatted as SEMVER style string.
* See https://semver.org/ for more information.
*/
#define VERSION "0.4.5-Dev"
#endif
/**
* Set the default Serial baudrate in bits/seconds
*/
#define CONFIG_SERIAL_BAUDRATE 115200
/**
* Pin ID of the output relay
*/
#define CONFIG_IO_RELAY D1
/**
* Pin ID of the DHT11 temperature sensor
*/
#define CONFIG_IO_DHT11 D2
/**
* Interval at which the tempreature is sent in seconds
*/
#define CONFIG_TEMPERATURE_SEND_INTERVAL 60
#endif

@ -1,20 +1,38 @@
/**
* \brief Entry point
*
* Deskcontrol is a simple on/off timer switch inteded for use with an ATX PSU.
* The theory of operation is turning on and off power by pulling the control line low/high while
* running of the 5V standby line.
*
* Additional features include support for a DHT11 to log the temperature.
* \file
*/
#include "config.h"
#include <Homie.h>
#include <LoggerNode.h>
LoggerNode LN;
LoggerNode LN; ///<Instance of the LoggerNode library
#include "DHTesp.h"
DHTesp dht;
DHTesp dht; ///< Instance of the DHT temperature controller.
#define OUTPUT_SET(x) digitalWrite(CONFIG_IO_RELAY, x ? LOW : HIGH)
unsigned int timer = 0;
unsigned int next_timer_update = 0;
#define OUTPUT_SET(x) digitalWrite(CONFIG_IO_RELAY, x ? LOW : HIGH) ///< Macro for controlling the output state.
unsigned int timer = 0; ///< Remaining time when counting down.
unsigned int next_timer_update = 0; ///< Timer used to control when the timer value should be pushed to the server
HomieNode powerNode("power", "Power", "switch");
HomieNode temperatureNode("temperature", "Temperature", "temperature");
/** Power state handler
* Handles event on the power state MQTT node
* \param[in] range Currently unused
* \param[in] value New value of the power state. (Either "on" or off")
* \return False if input is invalid. Otherwise true.
*/
bool powerStateHandler(const HomieRange& range, const String& value)
{
if (value != "on" && value != "off")
@ -38,6 +56,13 @@ bool powerStateHandler(const HomieRange& range, const String& value)
return true;
}
/**
* \brief powerTimer event handler.
* Handler for events on the powerTimer node.
* \param[in] range Currently unused.
* \param[in] value New value for the timer in minutes. ASCII representation of an integer from 1 to 120.
* \return False if input is invalid. Otherwise true.
*/
bool powerTimerHandler(const HomieRange& range, const String& value)
{
int settimer = value.toInt();
@ -53,10 +78,11 @@ bool powerTimerHandler(const HomieRange& range, const String& value)
return true;
}
/**
* setupHandler. Comply with Homie interface
*/
void setupHandler()
{
pinMode(CONFIG_IO_RELAY, OUTPUT);
OUTPUT_SET(false);
powerNode.setProperty("state").send("off");
@ -65,6 +91,9 @@ void setupHandler()
dht.setup(CONFIG_IO_DHT11, DHTesp::DHT11); // Connect DHT sensor to GPIO 17
}
/**
* Handle timer updates from the main event loop
*/
void loopHandleTimer()
{
if(timer)
@ -87,6 +116,9 @@ void loopHandleTimer()
}
}
/**
* Handle periodic temperature measurements from the main event loop
*/
void loopHandleTemperature()
{
static unsigned long lastTemperatureSent = 0;
@ -101,12 +133,21 @@ void loopHandleTemperature()
}
}
/**
* Main event loop. Part of the Homie API. This runs while the device is active and connected.
*
* \callgraph
*/
void loopHandler()
{
loopHandleTimer();
loopHandleTemperature();
}
/**
* Arduino style setup() routine.
* Configure the Homie framework by adding the two nodes "power" and "temperature"
*/
void setup()
{
@ -130,6 +171,9 @@ void setup()
Homie.setup();
}
/**
* Arduino main loop. Forwarded to Homie framework
*/
void loop()
{
Homie.loop();