Compare commits
No commits in common. "master" and "v0.3.1" have entirely different histories.
11
.drone.yml
11
.drone.yml
@ -16,17 +16,10 @@ steps:
|
|||||||
- name: release
|
- name: release
|
||||||
image: plugins/gitea-release
|
image: plugins/gitea-release
|
||||||
settings:
|
settings:
|
||||||
api_key:
|
api_key: a7f3afc9f77e721951e48b4af66d7565700b7a2e
|
||||||
from_secret: DRONE_ACCESS_TOKEN
|
|
||||||
base_url: https://code.jcktrue.dk
|
base_url: https://code.jcktrue.dk
|
||||||
files:
|
files:
|
||||||
- .pio/build/nodemcu/firmware.bin
|
- .pio/build/nodemcu/firmware.bin
|
||||||
checksum:
|
- .pio/build/nodemcu/firmware.elf
|
||||||
- md5
|
|
||||||
- sha1
|
|
||||||
- sha256
|
|
||||||
- sha512
|
|
||||||
- adler32
|
|
||||||
- crc32
|
|
||||||
when:
|
when:
|
||||||
event: tag
|
event: tag
|
||||||
|
5
.gitignore
vendored
5
.gitignore
vendored
@ -1,4 +1,5 @@
|
|||||||
|
.pioenvs
|
||||||
|
.piolibdeps
|
||||||
.pio
|
.pio
|
||||||
data/homie/config.json
|
data/homie/config.json
|
||||||
.vscode
|
nbproject
|
||||||
output/doxygen
|
|
||||||
|
3
Makefile
3
Makefile
@ -4,6 +4,3 @@ build:
|
|||||||
otaupload:
|
otaupload:
|
||||||
pip install -r .pio/libdeps/nodemcu/Homie/scripts/ota_updater/requirements.txt
|
pip install -r .pio/libdeps/nodemcu/Homie/scripts/ota_updater/requirements.txt
|
||||||
python .pio/libdeps/nodemcu/Homie/scripts/ota_updater/ota_updater.py -l mqtt.jcktrue.dk -i 18fe34f2f987 .pio/build/nodemcu/firmware.bin
|
python .pio/libdeps/nodemcu/Homie/scripts/ota_updater/ota_updater.py -l mqtt.jcktrue.dk -i 18fe34f2f987 .pio/build/nodemcu/firmware.bin
|
||||||
|
|
||||||
docs:
|
|
||||||
doxygen .\.doxygen
|
|
||||||
|
@ -1,15 +0,0 @@
|
|||||||
{
|
|
||||||
"name": "deskcontrol",
|
|
||||||
"wifi": {
|
|
||||||
"ssid": "<SSID>",
|
|
||||||
"password": "<PASS>"
|
|
||||||
},
|
|
||||||
"mqtt": {
|
|
||||||
"host": "<Domain>",
|
|
||||||
"port": 1883,
|
|
||||||
"auth": false
|
|
||||||
},
|
|
||||||
"ota": {
|
|
||||||
"enabled": true
|
|
||||||
}
|
|
||||||
}
|
|
@ -1,36 +0,0 @@
|
|||||||
/**
|
|
||||||
* \file
|
|
||||||
* \class Config
|
|
||||||
*/
|
|
||||||
#ifndef CONFIG_H
|
|
||||||
#define CONFIG_H
|
|
||||||
|
|
||||||
#ifndef VERSION
|
|
||||||
//SEMVER style version
|
|
||||||
/**
|
|
||||||
* \brief Version string.
|
|
||||||
* Update as needed. Formatted as SEMVER style string.
|
|
||||||
* See https://semver.org/ for more information.
|
|
||||||
*/
|
|
||||||
#define VERSION "0.4.5-Dev"
|
|
||||||
#endif
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Set the default Serial baudrate in bits/seconds
|
|
||||||
*/
|
|
||||||
#define CONFIG_SERIAL_BAUDRATE 115200
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Pin ID of the output relay
|
|
||||||
*/
|
|
||||||
#define CONFIG_IO_RELAY D1
|
|
||||||
/**
|
|
||||||
* Pin ID of the DHT11 temperature sensor
|
|
||||||
*/
|
|
||||||
#define CONFIG_IO_DHT11 D2
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Interval at which the tempreature is sent in seconds
|
|
||||||
*/
|
|
||||||
#define CONFIG_TEMPERATURE_SEND_INTERVAL 60
|
|
||||||
#endif
|
|
@ -1,12 +1,27 @@
|
|||||||
[env]
|
#
|
||||||
platform = espressif8266
|
# Project Configuration File
|
||||||
framework = arduino
|
#
|
||||||
|
# A detailed documentation with the EXAMPLES is located here:
|
||||||
|
# http://docs.platformio.org/en/latest/projectconf.html
|
||||||
|
#
|
||||||
|
|
||||||
upload_speed=921600
|
# A sign `#` at the beginning of the line indicates a comment
|
||||||
|
# Comment lines are ignored.
|
||||||
|
|
||||||
build_flags = -DPIO_FRAMEWORK_ARDUINO_LWIP2_LOW_MEMORY -DVERSION=${sysenv.DRONE_SEMVER}
|
# Simple and base environment
|
||||||
lib_deps = https://github.com/homieiot/homie-esp8266.git#develop, DHT sensor library for ESPx, HomieLoggerNode
|
# [env:mybaseenv]
|
||||||
|
# platform = %INSTALLED_PLATFORM_NAME_HERE%
|
||||||
|
# framework =
|
||||||
|
# board =
|
||||||
|
#
|
||||||
|
# Automatic targets - enable auto-uploading
|
||||||
|
# targets = upload
|
||||||
|
|
||||||
[env:nodemcu]
|
[env:nodemcu]
|
||||||
|
platform = espressif8266
|
||||||
|
framework = arduino
|
||||||
board = nodemcu
|
board = nodemcu
|
||||||
|
upload_speed=921600
|
||||||
|
|
||||||
|
build_flags = -D PIO_FRAMEWORK_ARDUINO_LWIP2_LOW_MEMORY
|
||||||
|
lib_deps = https://github.com/homieiot/homie-esp8266.git#develop-v3, Syslog
|
||||||
|
180
src/main.cpp
180
src/main.cpp
@ -1,70 +1,32 @@
|
|||||||
/**
|
|
||||||
* \brief Entry point
|
|
||||||
*
|
|
||||||
* Deskcontrol is a simple on/off timer switch inteded for use with an ATX PSU.
|
|
||||||
* The theory of operation is turning on and off power by pulling the control line low/high while
|
|
||||||
* running of the 5V standby line.
|
|
||||||
*
|
|
||||||
* Additional features include support for a DHT11 to log the temperature.
|
|
||||||
* \file
|
|
||||||
*/
|
|
||||||
|
|
||||||
#include "config.h"
|
|
||||||
|
|
||||||
#include <Homie.h>
|
#include <Homie.h>
|
||||||
|
#include <Syslog.h>
|
||||||
|
#include <WiFiUdp.h>
|
||||||
|
WiFiUDP udpClient;
|
||||||
|
Syslog syslog(udpClient, SYSLOG_PROTO_IETF);
|
||||||
|
|
||||||
#include <LoggerNode.h>
|
const int PIN_RELAY = D1;
|
||||||
LoggerNode LN; ///<Instance of the LoggerNode library
|
#define OUTPUT_SET(x) digitalWrite(PIN_RELAY, x ? LOW : HIGH);
|
||||||
|
unsigned int timer = 0;
|
||||||
#include "DHTesp.h"
|
unsigned int next_timer_update = 0;
|
||||||
DHTesp dht; ///< Instance of the DHT temperature controller.
|
|
||||||
|
|
||||||
|
|
||||||
#define OUTPUT_SET(x) digitalWrite(CONFIG_IO_RELAY, x ? LOW : HIGH) ///< Macro for controlling the output state.
|
|
||||||
unsigned int timer = 0; ///< Remaining time when counting down.
|
|
||||||
unsigned int next_timer_update = 0; ///< Timer used to control when the timer value should be pushed to the server
|
|
||||||
|
|
||||||
HomieNode powerNode("power", "Power", "switch");
|
HomieNode powerNode("power", "Power", "switch");
|
||||||
HomieNode temperatureNode("temperature", "Temperature", "temperature");
|
|
||||||
|
|
||||||
/** Power state handler
|
bool powerStateHandler(const HomieRange& range, const String& value) {
|
||||||
* Handles event on the power state MQTT node
|
if (value != "on" && value != "off") return false;
|
||||||
* \param[in] range Currently unused
|
|
||||||
* \param[in] value New value of the power state. (Either "on" or off")
|
|
||||||
* \return False if input is invalid. Otherwise true.
|
|
||||||
*/
|
|
||||||
bool powerStateHandler(const HomieRange& range, const String& value)
|
|
||||||
{
|
|
||||||
if (value != "on" && value != "off")
|
|
||||||
{
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
powerNode.setProperty("state").send(value);
|
powerNode.setProperty("state").send(value);
|
||||||
powerNode.setProperty("timer").send("0");
|
powerNode.setProperty("timer").send("0");
|
||||||
timer = 0;
|
timer = 0;
|
||||||
|
if(value == "on") {
|
||||||
if(value == "on")
|
|
||||||
{
|
|
||||||
OUTPUT_SET(true);
|
OUTPUT_SET(true);
|
||||||
LN.logf(__PRETTY_FUNCTION__, LoggerNode::INFO, "Power ON");
|
Homie.getLogger() << "Power is on" << endl;
|
||||||
}
|
} else {
|
||||||
else
|
OUTPUT_SET(false);
|
||||||
{
|
Homie.getLogger() << "Power is off" << endl;
|
||||||
OUTPUT_SET(false); LN.logf(__PRETTY_FUNCTION__, LoggerNode::INFO, "Power OFF");
|
|
||||||
}
|
}
|
||||||
|
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
bool powerTimerHandler(const HomieRange& range, const String& value) {
|
||||||
* \brief powerTimer event handler.
|
|
||||||
* Handler for events on the powerTimer node.
|
|
||||||
* \param[in] range Currently unused.
|
|
||||||
* \param[in] value New value for the timer in minutes. ASCII representation of an integer from 1 to 120.
|
|
||||||
* \return False if input is invalid. Otherwise true.
|
|
||||||
*/
|
|
||||||
bool powerTimerHandler(const HomieRange& range, const String& value)
|
|
||||||
{
|
|
||||||
int settimer = value.toInt();
|
int settimer = value.toInt();
|
||||||
if(settimer == 0 || settimer > 120)
|
if(settimer == 0 || settimer > 120)
|
||||||
return false;
|
return false;
|
||||||
@ -73,108 +35,86 @@ bool powerTimerHandler(const HomieRange& range, const String& value)
|
|||||||
next_timer_update = millis() + 60*1000;
|
next_timer_update = millis() + 60*1000;
|
||||||
powerNode.setProperty("timer").send(String(settimer));
|
powerNode.setProperty("timer").send(String(settimer));
|
||||||
powerNode.setProperty("state").send("on");
|
powerNode.setProperty("state").send("on");
|
||||||
LN.logf(__PRETTY_FUNCTION__, LoggerNode::INFO, "Power on for %d minutes", settimer);
|
Homie.getLogger() << "Power is on for " << settimer << "minutes" << endl;
|
||||||
OUTPUT_SET(true);
|
OUTPUT_SET(true);
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
|
||||||
* setupHandler. Comply with Homie interface
|
|
||||||
*/
|
|
||||||
void setupHandler()
|
|
||||||
{
|
|
||||||
pinMode(CONFIG_IO_RELAY, OUTPUT);
|
|
||||||
OUTPUT_SET(false);
|
|
||||||
powerNode.setProperty("state").send("off");
|
|
||||||
powerNode.setProperty("timer").send("0");
|
|
||||||
|
|
||||||
dht.setup(CONFIG_IO_DHT11, DHTesp::DHT11); // Connect DHT sensor to GPIO 17
|
void setupHandler() {
|
||||||
|
pinMode(PIN_RELAY, OUTPUT);
|
||||||
|
OUTPUT_SET(false);
|
||||||
|
powerNode.setProperty("state").send("off");
|
||||||
|
powerNode.setProperty("timer").send("0");
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
void loopHandler() {
|
||||||
* Handle timer updates from the main event loop
|
|
||||||
*/
|
|
||||||
void loopHandleTimer()
|
|
||||||
{
|
|
||||||
if(timer)
|
if(timer)
|
||||||
{
|
{
|
||||||
if(timer < millis())
|
if(timer < millis())
|
||||||
{ //Timer has expired. (Ignore the wraparound...)
|
{
|
||||||
timer = 0;
|
timer = 0;
|
||||||
OUTPUT_SET(false);
|
OUTPUT_SET(false);
|
||||||
powerNode.setProperty("timer").send("0");
|
powerNode.setProperty("timer").send("0");
|
||||||
powerNode.setProperty("state").send("off");
|
powerNode.setProperty("state").send("off");
|
||||||
}
|
}
|
||||||
|
if(millis() > next_timer_update) {
|
||||||
if(next_timer_update && millis() > next_timer_update)
|
|
||||||
{
|
|
||||||
next_timer_update = millis() + 60*1000;
|
next_timer_update = millis() + 60*1000;
|
||||||
unsigned int time_remaining = timer - millis();
|
unsigned int time_remaining = timer - millis();
|
||||||
unsigned int min_left = time_remaining / (60*1000);
|
unsigned int min_left = time_remaining / (60*1000);
|
||||||
powerNode.setProperty("timer").send(String(min_left));
|
powerNode.setProperty("timer").send(String(min_left));
|
||||||
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
void onHomieEvent(const HomieEvent& event) {
|
||||||
* Handle periodic temperature measurements from the main event loop
|
switch(event.type) {
|
||||||
*/
|
case HomieEventType::OTA_FAILED:
|
||||||
void loopHandleTemperature()
|
syslog.log(LOG_INFO, "OTA failed");
|
||||||
{
|
// Do whatever you want when OTA is failed
|
||||||
static unsigned long lastTemperatureSent = 0;
|
break;
|
||||||
if (millis() - lastTemperatureSent >= CONFIG_TEMPERATURE_SEND_INTERVAL * 1000UL || lastTemperatureSent == 0)
|
case HomieEventType::OTA_SUCCESSFUL:
|
||||||
{
|
syslog.log(LOG_INFO, "OTA completed");
|
||||||
float humidity = dht.getHumidity();
|
break;
|
||||||
float temperature = dht.getTemperature();
|
case HomieEventType::WIFI_CONNECTED:
|
||||||
LN.logf(__PRETTY_FUNCTION__, LoggerNode::DEBUG, "Temperature: %f C Humidity: %f", temperature, humidity);
|
// Do whatever you want when Wi-Fi is connected in normal mode
|
||||||
temperatureNode.setProperty("temperature").send(String(temperature));
|
syslog.deviceHostname(Homie.getConfiguration().name);
|
||||||
temperatureNode.setProperty("humidity").send(String(humidity));
|
syslog.appName("deskcontrol");
|
||||||
lastTemperatureSent = millis();
|
syslog.defaultPriority(LOG_ERR);
|
||||||
|
syslog.log(LOG_INFO, "WiFi Connected, software version: 1.0");
|
||||||
|
break;
|
||||||
|
case HomieEventType::MQTT_READY:
|
||||||
|
syslog.log(LOG_INFO, "MQTT connected");
|
||||||
|
break;
|
||||||
|
case HomieEventType::MQTT_DISCONNECTED:
|
||||||
|
syslog.log(LOG_INFO, "MQTT disconnected");
|
||||||
|
break;
|
||||||
|
default:
|
||||||
|
break;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
void setup() {
|
||||||
* Main event loop. Part of the Homie API. This runs while the device is active and connected.
|
syslog.server("192.168.1.100", 514);
|
||||||
*
|
|
||||||
* \callgraph
|
|
||||||
*/
|
|
||||||
void loopHandler()
|
|
||||||
{
|
|
||||||
loopHandleTimer();
|
|
||||||
loopHandleTemperature();
|
|
||||||
}
|
|
||||||
|
|
||||||
/**
|
Serial.begin(115200);
|
||||||
* Arduino style setup() routine.
|
|
||||||
* Configure the Homie framework by adding the two nodes "power" and "temperature"
|
|
||||||
*/
|
|
||||||
void setup()
|
|
||||||
{
|
|
||||||
|
|
||||||
Homie_setFirmware("deskcontrol", VERSION);
|
Serial << endl << endl;
|
||||||
Homie.setLoggingPrinter(&Serial);
|
Serial << "Firmware 0.0.1" << endl;
|
||||||
Serial.begin(CONFIG_SERIAL_BAUDRATE);
|
Serial << endl << endl;
|
||||||
|
|
||||||
Homie.disableResetTrigger();
|
Homie_setFirmware("deskcontrol", "1.0.0");
|
||||||
|
Homie_setBrand("FuryFire");
|
||||||
|
|
||||||
//Power
|
|
||||||
powerNode.advertise("state").settable(powerStateHandler);
|
powerNode.advertise("state").settable(powerStateHandler);
|
||||||
powerNode.advertise("timer").settable(powerTimerHandler);
|
powerNode.advertise("timer").settable(powerTimerHandler);
|
||||||
|
|
||||||
//Temperature
|
|
||||||
temperatureNode.advertise("humidity");
|
|
||||||
temperatureNode.advertise("temperature");
|
|
||||||
|
|
||||||
Homie.setSetupFunction(setupHandler);
|
Homie.setSetupFunction(setupHandler);
|
||||||
|
Homie.onEvent(onHomieEvent); // before Homie.setup()
|
||||||
Homie.setLoopFunction(loopHandler);
|
Homie.setLoopFunction(loopHandler);
|
||||||
|
|
||||||
Homie.setup();
|
Homie.setup();
|
||||||
}
|
}
|
||||||
|
|
||||||
/**
|
void loop() {
|
||||||
* Arduino main loop. Forwarded to Homie framework
|
|
||||||
*/
|
|
||||||
void loop()
|
|
||||||
{
|
|
||||||
Homie.loop();
|
Homie.loop();
|
||||||
}
|
}
|
||||||
|
Loading…
Reference in New Issue
Block a user