More doxygen comments added.
All checks were successful
continuous-integration/drone/push Build is passing

This commit is contained in:
Jens True 2020-12-12 17:48:36 +01:00
parent 602ec3add6
commit 0067a0b8a9

@ -17,17 +17,21 @@
LoggerNode LN; ///<Instance of the LoggerNode library
#include "DHTesp.h"
DHTesp dht; ///< DHT instance
DHTesp dht; ///< Instance of the DHT temperature controller.
#define OUTPUT_SET(x) digitalWrite(CONFIG_IO_RELAY, x ? LOW : HIGH)
unsigned int timer = 0;
unsigned int next_timer_update = 0;
#define OUTPUT_SET(x) digitalWrite(CONFIG_IO_RELAY, x ? LOW : HIGH) ///< Macro for controlling the output state.
unsigned int timer = 0; ///< Remaining time when counting down.
unsigned int next_timer_update = 0; ///< Timer used to control when the timer value should be pushed to the server
HomieNode powerNode("power", "Power", "switch");
HomieNode temperatureNode("temperature", "Temperature", "temperature");
/** Power state handler
* Handes event on the power state MQTT node
* Handles event on the power state MQTT node
* \param[in] range Currently unused
* \param[in] value New value of the power state. (Either "on" or off")
* \return False if input is invalid. Otherwise true.
*/
bool powerStateHandler(const HomieRange& range, const String& value)
{
@ -53,7 +57,11 @@ bool powerStateHandler(const HomieRange& range, const String& value)
}
/**
* Handler for events on the powerTimer node
* \brief powerTimer event handler.
* Handler for events on the powerTimer node.
* \param[in] range Currently unused.
* \param[in] value New value for the timer in minutes. ASCII representation of an integer from 1 to 120.
* \return False if input is invalid. Otherwise true.
*/
bool powerTimerHandler(const HomieRange& range, const String& value)
{
@ -70,10 +78,11 @@ bool powerTimerHandler(const HomieRange& range, const String& value)
return true;
}
/**
* setupHandler. Comply with Homie interface
*/
void setupHandler()
{
pinMode(CONFIG_IO_RELAY, OUTPUT);
OUTPUT_SET(false);
powerNode.setProperty("state").send("off");
@ -82,6 +91,9 @@ void setupHandler()
dht.setup(CONFIG_IO_DHT11, DHTesp::DHT11); // Connect DHT sensor to GPIO 17
}
/**
* Handle timer updates from the main event loop
*/
void loopHandleTimer()
{
if(timer)
@ -104,6 +116,9 @@ void loopHandleTimer()
}
}
/**
* Handle periodic temperature measurements from the main event loop
*/
void loopHandleTemperature()
{
static unsigned long lastTemperatureSent = 0;
@ -119,7 +134,8 @@ void loopHandleTemperature()
}
/**
* Main event loop
* Main event loop. Part of the Homie API. This runs while the device is active and connected.
*
* \callgraph
*/
void loopHandler()
@ -128,6 +144,10 @@ void loopHandler()
loopHandleTemperature();
}
/**
* Arduino style setup() routine.
* Configure the Homie framework by adding the two nodes "power" and "temperature"
*/
void setup()
{
@ -151,6 +171,9 @@ void setup()
Homie.setup();
}
/**
* Arduino main loop. Forwarded to Homie framework
*/
void loop()
{
Homie.loop();